Light · energy · costs

Crop calculators

Review version

How much supplemental light, at what cost?

Compare the daily light dose and running costs of the same fixtures under two control strategies.

Potworów, Mazovia, PolandRed sweet pepper · Muriel F1 · fruiting
Your crop
30/07/2026 — 28/08/2026
30/06/202628/08/2026

Daily light integral at crop level

mol/m²/day
Fixed scheduleDLI control + shadingDLI target ±10%
Daily light integral at crop levelPoint to a day or use the keyboard arrow keys. Both lines use the same number of fixtures.01020304030 Jul13 Aug28 Aug
28 AugustFixed schedule: 27.9DLI control + shading: 26.6mol/m²/day

Point to a day or use the keyboard arrow keys. Both lines use the same number of fixtures.

Less lighting energy

3,464 kWh88% less than the fixed schedule

Electricity cost difference

3,464 PLNfor your area · 34,636 PLN / ha

Days within target range

6 / 303 / 30 with the fixed schedule
Source: NASA POWER · daily data for the Potworów area

In-tunnel DLI and the hourly profile are estimates. This is a simulation, not measurements from your crop.

Checking for newer data…

Estimated fixture sizing

49 800 W LED fixtures

for your area · 490 / ha

Installed power39.2 kW
Supplemental PPFD94 µmol/m²/s

Sized for the full available period; moving the dates does not change the installation. Model limit: 300 µmol/m²/s of supplemental light.

Lighting electricity cost

Fixed schedule: 3,925 PLN

DLI control + shading: 461 PLN

Show daily results
Both scenarios use the same number of fixtures.
DayNatural lightmol/m²/dayFixed schedulemol/m²/dayDLI control + shadingmol/m²/dayLighting hours: schedule / DLIEnergy: schedule / DLIkWh
30/07/202632.733.632.72.5 / 098.5 / 0
31/07/202629.230.129.22.6 / 0100.6 / 0
01/08/20262727.9272.6 / 0102.7 / 0
02/08/202625.426.325.42.7 / 0104.8 / 0
03/08/202631.632.631.62.7 / 0107 / 0
04/08/202631.632.631.62.8 / 0109.1 / 0
05/08/202631.532.531.52.8 / 0111.4 / 0
06/08/202631.132.131.12.9 / 0113.6 / 0
07/08/202620.721.720.73 / 0115.9 / 0
08/08/202627.128.227.13 / 0118.1 / 0
09/08/202632.333.332.33.1 / 0120.4 / 0
10/08/202629.530.629.53.1 / 0122.8 / 0
11/08/202624.225.324.23.2 / 0125.1 / 0
12/08/202626.227.326.23.3 / 0127.5 / 0
13/08/202624.625.724.63.3 / 0129.9 / 0
14/08/202630.631.730.63.4 / 0132.3 / 0
15/08/202630.331.530.33.4 / 0134.7 / 0
16/08/202629.530.629.53.5 / 0137.1 / 0
17/08/202620.922.120.93.6 / 0139.6 / 0
18/08/20262021.3203.6 / 0142 / 0
19/08/202621.122.321.13.7 / 0144.5 / 0
20/08/202626.427.726.43.8 / 0147 / 0
21/08/202621.322.621.33.8 / 0149.5 / 0
22/08/202616.617.917.93.9 / 3.9152 / 152
23/08/202618.720203.9 / 3.9154.6 / 152.2
24/08/202614.215.615.64 / 4156.8 / 156.8
25/08/202623.624.923.64 / 0156.8 / 0
26/08/202626.928.226.94 / 0156.8 / 0
27/08/202626.127.526.14 / 0156.8 / 0
28/08/202626.627.926.64 / 0156.8 / 0
Assumptions and calculations
  1. Daily NASA POWER data describe outdoor solar radiation. They represent the source grid area, not measurements in a particular polytunnel. Dates reflect data availability.
  2. Light dose is estimated from solar energy and cover transmission: kWh/m² × 7.272 × transmission = mol/m²/day. The sunlight conversion is approximate. The within-day light profile is modelled from day length; it does not reconstruct actual hourly cloud cover.
  3. Reference fixture: 800 W, efficacy 3 µmol/J, with 80% of the photon output reaching the growing area. These are comparison assumptions, not a specific product specification. Sizing uses the 80th percentile of demand across all 60 days, capped at 300 µmol/m²/s. The installation may be insufficient on the darkest days.
  4. Both scenarios use the same number of fixtures. The fixed schedule runs after dusk for the selected time, shortened to preserve at least 6 hours of darkness. DLI control only fills the remaining daily deficit, after the end of daylight, within the same available time.
  5. In the DLI scenario, a movable screen reduces modelled instantaneous PPFD above 1000 µmol/m²/s, by at most 50%. The fixed schedule assumes an open screen. This threshold is a simulation assumption, not an agronomic recommendation. Shading does not guarantee lower temperatures; temperature and ventilation are not modelled.
  6. The target band is the selected DLI ±10%. Costs cover fixture electricity at a flat kWh tariff only, excluding equipment, installation, heating, motors and cooling. The result is neither investment profit nor a prediction of additional crop yield.

Sources and further reading

Check this against measurements in your polytunnel

Weather data provide a starting point. A light sensor shows how much energy actually reaches your plants.

Let’s discuss your crop