Less lighting energy
3,464 kWh88% less than the fixed scheduleLight · energy · costs
Crop calculators
How much supplemental light, at what cost?
Compare the daily light dose and running costs of the same fixtures under two control strategies.
Daily light integral at crop level
mol/m²/dayPoint to a day or use the keyboard arrow keys. Both lines use the same number of fixtures.
Electricity cost difference
3,464 PLNfor your area · 34,636 PLN / haDays within target range
6 / 303 / 30 with the fixed scheduleIn-tunnel DLI and the hourly profile are estimates. This is a simulation, not measurements from your crop.
Estimated fixture sizing
49 800 W LED fixturesfor your area · 490 / ha
Sized for the full available period; moving the dates does not change the installation. Model limit: 300 µmol/m²/s of supplemental light.
Fixed schedule: 3,925 PLN
DLI control + shading: 461 PLN
Show daily results
| Day | Natural lightmol/m²/day | Fixed schedulemol/m²/day | DLI control + shadingmol/m²/day | Lighting hours: schedule / DLI | Energy: schedule / DLIkWh |
|---|---|---|---|---|---|
| 30/07/2026 | 32.7 | 33.6 | 32.7 | 2.5 / 0 | 98.5 / 0 |
| 31/07/2026 | 29.2 | 30.1 | 29.2 | 2.6 / 0 | 100.6 / 0 |
| 01/08/2026 | 27 | 27.9 | 27 | 2.6 / 0 | 102.7 / 0 |
| 02/08/2026 | 25.4 | 26.3 | 25.4 | 2.7 / 0 | 104.8 / 0 |
| 03/08/2026 | 31.6 | 32.6 | 31.6 | 2.7 / 0 | 107 / 0 |
| 04/08/2026 | 31.6 | 32.6 | 31.6 | 2.8 / 0 | 109.1 / 0 |
| 05/08/2026 | 31.5 | 32.5 | 31.5 | 2.8 / 0 | 111.4 / 0 |
| 06/08/2026 | 31.1 | 32.1 | 31.1 | 2.9 / 0 | 113.6 / 0 |
| 07/08/2026 | 20.7 | 21.7 | 20.7 | 3 / 0 | 115.9 / 0 |
| 08/08/2026 | 27.1 | 28.2 | 27.1 | 3 / 0 | 118.1 / 0 |
| 09/08/2026 | 32.3 | 33.3 | 32.3 | 3.1 / 0 | 120.4 / 0 |
| 10/08/2026 | 29.5 | 30.6 | 29.5 | 3.1 / 0 | 122.8 / 0 |
| 11/08/2026 | 24.2 | 25.3 | 24.2 | 3.2 / 0 | 125.1 / 0 |
| 12/08/2026 | 26.2 | 27.3 | 26.2 | 3.3 / 0 | 127.5 / 0 |
| 13/08/2026 | 24.6 | 25.7 | 24.6 | 3.3 / 0 | 129.9 / 0 |
| 14/08/2026 | 30.6 | 31.7 | 30.6 | 3.4 / 0 | 132.3 / 0 |
| 15/08/2026 | 30.3 | 31.5 | 30.3 | 3.4 / 0 | 134.7 / 0 |
| 16/08/2026 | 29.5 | 30.6 | 29.5 | 3.5 / 0 | 137.1 / 0 |
| 17/08/2026 | 20.9 | 22.1 | 20.9 | 3.6 / 0 | 139.6 / 0 |
| 18/08/2026 | 20 | 21.3 | 20 | 3.6 / 0 | 142 / 0 |
| 19/08/2026 | 21.1 | 22.3 | 21.1 | 3.7 / 0 | 144.5 / 0 |
| 20/08/2026 | 26.4 | 27.7 | 26.4 | 3.8 / 0 | 147 / 0 |
| 21/08/2026 | 21.3 | 22.6 | 21.3 | 3.8 / 0 | 149.5 / 0 |
| 22/08/2026 | 16.6 | 17.9 | 17.9 | 3.9 / 3.9 | 152 / 152 |
| 23/08/2026 | 18.7 | 20 | 20 | 3.9 / 3.9 | 154.6 / 152.2 |
| 24/08/2026 | 14.2 | 15.6 | 15.6 | 4 / 4 | 156.8 / 156.8 |
| 25/08/2026 | 23.6 | 24.9 | 23.6 | 4 / 0 | 156.8 / 0 |
| 26/08/2026 | 26.9 | 28.2 | 26.9 | 4 / 0 | 156.8 / 0 |
| 27/08/2026 | 26.1 | 27.5 | 26.1 | 4 / 0 | 156.8 / 0 |
| 28/08/2026 | 26.6 | 27.9 | 26.6 | 4 / 0 | 156.8 / 0 |
Assumptions and calculations
- Daily NASA POWER data describe outdoor solar radiation. They represent the source grid area, not measurements in a particular polytunnel. Dates reflect data availability.
- Light dose is estimated from solar energy and cover transmission: kWh/m² × 7.272 × transmission = mol/m²/day. The sunlight conversion is approximate. The within-day light profile is modelled from day length; it does not reconstruct actual hourly cloud cover.
- Reference fixture: 800 W, efficacy 3 µmol/J, with 80% of the photon output reaching the growing area. These are comparison assumptions, not a specific product specification. Sizing uses the 80th percentile of demand across all 60 days, capped at 300 µmol/m²/s. The installation may be insufficient on the darkest days.
- Both scenarios use the same number of fixtures. The fixed schedule runs after dusk for the selected time, shortened to preserve at least 6 hours of darkness. DLI control only fills the remaining daily deficit, after the end of daylight, within the same available time.
- In the DLI scenario, a movable screen reduces modelled instantaneous PPFD above 1000 µmol/m²/s, by at most 50%. The fixed schedule assumes an open screen. This threshold is a simulation assumption, not an agronomic recommendation. Shading does not guarantee lower temperatures; temperature and ventilation are not modelled.
- The target band is the selected DLI ±10%. Costs cover fixture electricity at a flat kWh tariff only, excluding equipment, installation, heating, motors and cooling. The result is neither investment profit nor a prediction of additional crop yield.
Sources and further reading
Check this against measurements in your polytunnel
Weather data provide a starting point. A light sensor shows how much energy actually reaches your plants.

